Fatigue analysis of the steam generator of a parabolic trough solar power plant Articles
Overview
published in
- Energy Journal
publication date
- July 2018
start page
- 565
end page
- 577
volume
- 155
Digital Object Identifier (DOI)
full text
International Standard Serial Number (ISSN)
- 0360-5442
Electronic International Standard Serial Number (EISSN)
- 1873-6785
abstract
- This work proposes a methodology to perform the fatigue analysis of the steam generator of a parabolic trough power plant. The following methodology assumes cycling duty scenario (300 start-ups and shut downs per year). Two start-up operations of the steam generator are analyzed: evaporator temperature ramp and heat transfer fluid temperature ramp. Furthermore, a part load operation is studied. The results show that the most compromised parts of the steam generator are the reheater tubesheet for the TEMA CFU design, the steam drum-downcomer junction and the superheater nozzle. Besides, former reheater design (TEMA CFU) does not fulfil the 25-year lifetime condition. To overcome this problem, two alternative designs for the reheater are proposed: U-shell and two TEMA CFU in series. Finally, the lifetimes of TEMA NXU and kettle evaporator designs are compared. Our results show that TEMA NXU allows temperature ramps up to 9 degrees C/min without putting the steam generator lifetime at risk, whereas kettle temperature ramps greater than 5 degrees C/min do not fulfil the designed lifetime of 25 years. Respect to the load changes, the evaporator drum is the most stressed element. A 50% load change produces a damage equivalent to 60% of the damage produced by a daily start-up/shut-down cycle.
Classification
subjects
- Renewable Energies
keywords
- parabolic trough plant; steam generator; stress analysis; fatigue analysis